P45B and P50B X-ray CT datasets

<p dir="ltr">X-ray computed tomography datasets of E-One Moli Energy P45B and P50B 21700 cylindrical cells. Includes projections, made up of 6 subscans across the height of the cells, and reconstructions. Scan parameters:</p><ul><li>Tube source: Tungsten</li><li>Voltage: 160 kV</li><li>Current: 187.5 mA</li><li>Voxel size: 19.947 μm</li><li>Exposure time: 600ms</li><li>Filter: 1mm thick Cu</li><li>Projections per sub scan: P45B 1811; P50B 1868</li></ul><p></p>